The image shown is for representation purposes only and may not reflect the actual product.
Diameters / Packaging
|
Diameters |
33 lb Spool |
|---|---|
| 0.040 in (1.0 mm) | ED036532 |
DETAILS
An engineered alloy providing superior impact toughness at low temperatures.
Features
- An engineered alloy providing superior impact toughness at low temperatures
- Q2 Lot® - Certificates showing actual wire composition and actual mechanical properties available online
- Microguard® Ultra provides superior feeding and arc stability throughout all four quadrants of the pipe
- ProTech® packaging system
- Meets NACE MR0175 for sour gas applications
- Test data available for SSC (NACE TM0177) & HIC (NACE TM0284)
Typical Applications
- Root pass welding
- Hot, fill and cap pass welding of up to X70 grade pipe
Welding Positions
- All
Shielding Gas
- 100% CO2, 75-95% Argon/ Balance CO2, Flow Rate: 30-50 CFH
Service Information
You May Also Need
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
CONFORMANCE
| CONFORMANCES | SPECIFICATION | CLASSIFICATION |
|---|---|---|
| AWS | AWS A5.18 | ER70S-6 |
| ABS | ABS - Part 2 | 3YSA |
| TUV | TUV ISO 14341-A | G 42 3 C1 3Si1, G 46 4 M21 3Si1, G 46 4 M31 3Si1 |
MECHANICAL PROPERTIES
| Classification | Shielding Gas | Polarity |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F) |
|---|---|---|---|---|---|---|
| ER70S-6 Requirement | 100% CO2 | DC+ | 400 (58) min. | 480 (70) min. | 22 min. | 27 (20) min. |
| Typical Result, As-welded | 100% CO2 | DC+ | 470 (68) | 580 (84) | 28 | 81-95 (60-70) |
WIRE COMPOSITION
| Classification | %C | %Cr | %Mn | %Ni | %P | %S | %Si | %V | %Total Cu |
|---|---|---|---|---|---|---|---|---|---|
| ER70S-6 Requirement | 0.06 - 0.15 | 0.15 max. | 1.40 - 1.85 | 0.15 max. | 0.025 max. | 0.035 max. | 0.80 - 1.15 | 0.03 max. | 0.50 max. |
| Typical Result | 0.10 | 0.03 | 1.46 | 0.01 | 0.005 | 0.009 | 0.82 | 0.003 max. | 0.17 |
TYPICAL OPERATING PROCEDURES
| Diameter | Shielding Gas | Polarity |
CTWD
mm (in.)⁽¹⁾ |
Wire Feed Speed
m/min (in/min) |
Voltage
volts |
Approx. Current
amps |
Melt-off Rate
kg/hr (lb/hr) |
|---|---|---|---|---|---|---|---|
| 1.0 mm (0.040 in) | 75-95% Ar / balance CO2 | DC+ | 12-19 (1/2-3/4) | 2.5-14.0 (100-550) | 19-31 | 105-320 | 1.0-5.2 (2.1-11.5) |
| 1.2 mm (0.047 in) | 75-95% Ar / balance CO2 | DC+ | 12-19 (1/2-3/4) | 3.2-12.7 (125-500) | 19-31 | 145-360 | 1.7-6.5 (3.7-14.3) |
NOTES
| Note |
|---|
| ⁽¹⁾ CTWD (Contact Tip to Work Distance). Subtract 1/4 in. (6.4 mm) to calculate Electrical Stickout. |