Hardfacing Consumables Family Group
Imaginea produsului este cu titlul de referinta si poate sa nu corespunda cu produsul actual.

Diametre / Ambalaj

Diametre
11.3 KG SPOOL
1.1 mm ED028176
1.6 mm ED028177

Lincore® 55-G

Sarma tubulara cu pulberi cu protectie de gaz (FCAW-G)

CLASIFICARI:
EN ISO : T Fe2

LINCORE® 55-G Wire for crane wheels, blower blades, bucket lips, dredge parts, and tillage tools (Metal to Metal or Metal to Earth).

DETALII

LINCORE® 55-G Produces a deposit which resists metal-to-metal wear and mild abrasion to be used on carbon steel and low alloy steel offers unlimited layers with proper preheat and interpass temperatures and procedures.

Caracteristici

  • Pentru a fi utilizat pe otel carbon si slab aliat
  • Straturi nelimitate, cu proceduri adecvate pentru temperaturile de preincalzire si intre straturi
  • Produce un metal depus care rezista la uzura metal pe metal si la abraziune usoara
  • Unlimited layers with proper preheat and interpass temperatures and procedures

Aplicații tipice

  • Discuri de franare, Cupe, Macarale, Zdrobitoare, Lame
  • Tragatoare, Role, Tamburi, Extrudoare, Ciocane
  • Piese turnate, Cuptoare, Incarcatoare, Exploatari forestiere, Moara
  • Echipamente miniere, Mixere, Vetre deschise, Table, Generatoare de putere
  • Cai de rulare, Role, Lopeti, Dinti, Carucioare, Roti.

Poziții de sudare

  • Toate

Gaz protector

  • 75-90% Argon / Balance CO2 98% Argon / 2% O2

S-ar putea să aveți nevoie și de

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. Pagina de căutare FDS

MECHANICAL PROPERTIES

Classification Shielding Gas Hardness Rockwell C
Typical Result 98% Ar, 2% O2 56-59
Typical Result 75% Ar, 25% CO2 59-61

DEPOSIT COMPOSITION

Classification Product Size Number of layer Shielding Gas %C %Cr %Mn %Mo %Si
Typical Result .045" (1.1 mm) 2 Layers 75% Ar, 25% CO2 0.39 5.6 1.2 0.6 0.8
Typical Result .045" (1.1 mm) 2 Layers 98% Ar, 2% O2 0.47 6.4 1.4 0.6 1.0
Typical Result 1/16" (1.6 mm) 2 Layers 75% Ar, 25% CO2 0.41 5.3 1.2 0.6 0.8
Typical Result 1/16" (1.6 mm) 2 Layers 98% Ar, 2% O2 0.45 5.5 1.2 0.6 1.0

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity ESO
mm (in.)
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Deposition Rate
kg/hr (lb/hr)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 5.1 (200) 27 165 2.0 (4.3)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 7.6 (300) 29 225 3.0 (6.7)
0.045 in (1.1 mm) 75% Ar / 25% CO2 DC+ 16 (5/8) 10.2 (400) 31 290 4.2 (9.2)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 5.1 (200) 25 145 2.1 (4.7)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 7.6 (300) 28 195 3.3 (7.2)
0.045 in (1.1 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 10.2 (400) 30 245 4.4 (9.7)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 5.1 (200) 25 145 2.3 (5.1)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 7.6 (300) 27 200 3.4 (7.5)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 8.9 (350) 28 225 3.9 (8.7)
0.045 in (1.1 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 10.2 (400) 29 250 4.4 (9.8)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 3.8 (150) 28 260 2.6 (5.8)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 6.4 (250) 30 340 4.7 (10.4)
1/16 in (1.6 mm) 75% Ar / 25% CO2 DC+ 20 (3/4) 8.9 (350) 32 420 6.8 (15.1)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 3.8 (150) 25 230 2.7 (6.0)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 6.4 (250) 27 315 4.9 (10.7)
1/16 in (1.6 mm) 90% Ar / 10% CO2 DC+ 20 (3/4) 8.9 (350) 29 400 7.0 (15.4)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 3.8 (150) 24 220 2.9 (6.4)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 6.4 (250) 26 315 5.0 (11.0)
1/16 in (1.6 mm) 98% Ar / 2% O2 DC+ 20 (3/4) 8.9 (350) 28 410 7.1 (15.7)

NOTES

Note
Interpass temperatures between 150°C (300°F) and 200°C (400°F) do not affect the hardness of Lincore® 55 significantly.