25lb plastic spool Innershield NR-305
The image shown is for representation purposes only and may not reflect the actual product.

Diameters / Packaging

Diameters
33 lb Spool
0.052 in (1.3 mm) ED036480

Metalshield® MC®-120

Metal-Cored Gas-Shielded (GMAW-C)

CLASSIFICATIONS:
AWS E120C-K4-H4 & E120T15-M20A6-K4-H4

Metalshield® MC®-120 from Lincoln Electric is a low alloy metal cored wire with low spatter and excellent arc stability.

DETAILS

Metalshield® MC®-120 from Lincoln Electric is a low alloy metal cored wire with low spatter and excellent arc stability.

Features

  • H4 diffusible hydrogen levels
  • Low spatter and excellent arc stability
  • Deoxidizing agents minimize pre- and post-weld clean up
  • Enhanced silicon island management
  • Low temperature impact properties – Charpy V-Notch test results capable of exceeding 27 J (20 ft•lbf) @ -51°C (-60°F)
  • Excellent bead shape and profile

Typical Applications

  • Robotics/hard automation
  • HSLA and quenched and tempered steels (i.e., HY-100 and ASTM A514)
  • Crane fabrication
  • Heavy equipment
  • Pressure vessels

Welding Positions

  • All

Shielding Gas

  • 75-90% Argon / Balance CO2, Flow Rate: 40-60 CFH

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.28 E120C-K4-H4
AWS AWS A5.36 E120T15-M20A6-K4-H4

MECHANICAL PROPERTIES

Classification Shielding Gas Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
Charpy V-Notch
J (ft-lbs) @ -51°C (-60°F)
E120C-K4-H4 750 (108) min. 830 (120) min. 15 min. Not Specified 27 (20) min.
E120T15-M20A6-K4-H4 740 (108) min. 830-970 (120-140) 14 min. Not Specified 27 (20) min.
Typical Result, As-welded 75% Ar, 25% CO2 790-800 (115-116) 855-860 (124-125) 22 60-70 (45-52) 40-45 (31-34)
Typical Result, As-welded 90% Ar, 10% CO2 820-860 (119-125) 880-915 (128-133) 21 50-70 (39-55) 45-46 (32-34)

DEPOSIT COMPOSITION

Classification Shielding Gas %C %Mn %Si %S %P %Cu %Ni %Cr %Mo %V Diffusible Hydrogen
mL/100g Weld Metal
E120C-K4-H4 Requirement 0.15 max. 0.75-2.25 0.80 max. 0.025 max. 0.025 max. 0.35 max. 0.50-2.50 0.15-0.65 0.25-0.65 0.03 max. 4.0 max.
E120T15-M20A6-K4-H4 Requirement 0.15 max. 1.20-2.25 0.80 max. 0.030 max. 0.030 max. Not Specified 1.75-2.60 0.20-0.60 0.20-0.65 0.03 max. 4 max.
Typical Result 75% Ar, 25% CO2 0.06-0.07 1.70-1.80 0.58-0.62 0.010 0.010 0.02 1.90-2.10 0.31-0.33 0.55-0.58 0.01 1.0-3.0
Typical Result 90% Ar, 10% CO2 0.06-0.08 1.80-1.90 0.60-0.66 0.020 0.010 0.02-0.03 1.90-2.10 0.31-0.33 0.56-0.63 0.01 1.0-3.0

TYPICAL OPERATING PROCEDURES

Diameter in (mm) Polarity Shielding Gas CTWD⁽¹⁾ mm (in) Wire Feed Speed m/min (in/min) Voltage (volts) Current (amps) Melt-Off Rate kg/hr (lb/hr) Deposition Rate kg/hr (lb/hr) Efficiency (%)
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 5.1 (200) 23-25 200 3.1 (6.8) 2.9 (6.5) 96
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1)) 6.4 (250) 25-27 230 3.9 (8.5) 3.7 (8.1) 95
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 8.9 (350) 27-29 320 5.8 (12.7) 5.4 (11.8) 93
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 11.4 (450) 29-31 370 7.3 (16.1) 7.2 (15.8) 98
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 14.0 (550) 31-33 420 9.0 (19.8) 8.7 (19.2) 97

NOTES

Name