50lb Fiber Spool Metalshield MC-6
The image shown is for representation purposes only and may not reflect the actual product.

Diameters / Packaging

Diameters
50 lb Spool Buy America
750 lb Accu-Trak® Drum Buy America
0.045 in (1.1 mm) ED038231 ED038232
0.052 in (1.3 mm) ED038234 ED038235
1/16 in (1.6 mm) ED038237 ED038238

Metalshield® MC-70 XLS® Buy America

Metal-Cored (GMAW-C)

CLASSIFICATIONS:
AWS E70C-6M-H4

Metalshield® MC-70 XLS™ Buy America from Lincoln Electric is a mild steel metal-cored wire designed with minimal silicon islands for an exceptionally clean weld surface and minimal post weld clean up.

DETAILS

Metalshield® MC-70 XLS™ from Lincoln Electric is a mild steel metal-cored wire designed with minimal silicon islands for an exceptionally clean weld surface and minimal post weld clean up.

Features

  • Minimal silicon islands for an exceptionally clean weld surface
  • Minimal post weld clean up
  • Best-in-class edge wetting for excellent bead appearance
  • Smooth, stable arc characteristics with low spatter levels
  • Tolerates welding over mill scale and rust
  • Low H4 diffusible hydrogen levels
  • High deposition rates and fast travel speeds
  • All packaging and diameters are available meeting Buy America & American Iron & Steel (AIS) standards.

Typical Applications

  • Robotics/ Hard Automation
  • Structural Fabrication
  • Heavy Fabrication
  • Pressure Vessels
  • Agriculture

Welding Positions

  • All

Shielding Gas

  • 75-92% Argon / Balance CO2, Flow rate: 40-60 CFH

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.18 E70C-6M-H4

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
E70C-6M-H4 Requirement 75-80% Ar, balance CO2 DC+ 400 (58) min. 480 (70) min. 22 min. 27 (20) min.
Typical Result, As-welded 75% Ar, 25% CO2 DC+ 3100-3520 (450-510) 3520-4070 (510-590) 26-30 54-102 (40-75)
Typical Result, As-welded 90% Ar, 10% CO2 DC+ 3100-3790 (450-550) 3790-4270 (550-620) 26-30 81-142 (60-105)

DEPOSIT COMPOSITION

Classification Shielding Gas Polarity %C %Cr %Mn %Mo %Ni %P %S %Si %Total Cu %V Diffusible Hydrogen
mL/100g Weld Metal
E70C-6M-H4 Requirement 75-80% Ar, balance CO2 DC+ 0.12 max. 0.20 max. 1.75 max. 0.30 max. 0.50 max. 0.03 max. 0.03 max. 0.90 max. 0.50 max. 0.08 max. 4 max.
Typical Result 75% Ar, 25% CO2 DC+ 0.04-0.07 0.01-0.03 1.25-1.55 0.01-0.02 0.30-0.40 0.00-0.01 0.01-0.02 0.55-0.80 0.01-0.05 0.01-0.02 2-4
Typical Result 90% Ar, 10% CO2 DC+ 0.04-0.07 0.01-0.03 1.25-1.60 0.01-0.02 0.30-0.40 0.00-0.01 0.01-0.02 0.60-0.85 0.01-0.05 0.01-0.02 2-4