DETAILS
Metalshield® MC®-90 from Lincoln Electric is a low alloy metal-cored wire designed for high strength welding where tensile requirements of 620 MPa (90ksi) are required.
Features
- H4 diffusible hydrogen levels
- Low spatter and excellent arc stability
- Deoxidizing agents minimize pre- and post-weld clean up
- Enhanced silicon island management
- Low temperature impact properties - charpy V-notch test results capable of exceeding 40 J (30 ft·lbf) at -51°C (-60°F)
- Excellent bead shape and profile
Typical Applications
- Robotics/hard automation
- HSLA steels (i.e., ASTM A678 and A710)
- Crane fabrication
- Structural
Welding Positions
- All
Shielding Gas
- Mixed Shielding Gas
Disclaimers
Service Information
Documentation
BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page
See test result disclaimer
CONFORMANCE
| CONFORMANCES | SPECIFICATION | CLASSIFICATION |
|---|---|---|
| AWS | AWS A5.28 | E90C-K3-H4 |
| AWS | AWS A5.36 | E90T15-M20A6-K3-H4, E90T15-M21A6-K3-H4 |
| CWB | CWB/CSA | E90C-K3 H4 |
| ISO | ISO | T62 6 T15-0 M A-N3M2 H5 |
MECHANICAL PROPERTIES
| Classification | Shielding Gas |
Yield Strength @ 0.2% Offset
MPa (ksi) |
Tensile Strength
MPa (ksi) |
Elongation
% |
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F) |
Charpy V-Notch
J (ft-lbs) @ -51°C (-60°F) |
|---|---|---|---|---|---|---|
| E90C-K3-H4 Requirement | 540 (78) min. | 620 (90) min. | 18 min. | Not Specified | 27 (20) min. | |
| E90T15-M20A6-K3-H4 Requirement | 540 (78) min. | 620-760 (90-110) | 17 min. | Not Specified | 27 (20) min. | |
| Typical Result, As-welded | 75% Ar, 25% CO2 | 585-685 (85-100) | 655-755 (95-105) | 19-27 | 60-93 (44-68) | 36-87 (27-64) |
| Typical Result, As-welded | 90% Ar, 10% CO2 | 585-725 (85-105) | 655-825 (95-120) | 18-25 | 41-100 (30-74) | 27-91 (20-67) |
DEPOSIT COMPOSITION
| Classification | Shielding Gas | %C | %Mn | %Si | %S | %P | %Cu | %Ni | %Cr | %Mo | %V | %B |
Diffusible Hydrogen
mL/100g Weld Metal |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| E90C-K3-H4 Requirement | 0.15 max. | 0.75-2.25 | 0.80 max. | 0.025 max. | 0.025 max. | 0.35 max. | 0.50-2.50 | 0.15 max. | 0.25-0.65 | 0.03 max. | Not Specified | 4.0 max. | |
| E90T15-M20A6-K3-H4 Requirement | 0.15 max. | 0.75-2.25 | 0.80 max. | 0.030 max. | 0.030 max. | Not Specified | 1.25-2.60 | 0.15 max. | 0.25-0.65 | 0.05 max. | Not Specified | 4 max. | |
| Typical Result | 75% Ar, 25% CO2 | 0.04-0.08 | 1.00-1.51 | 0.20-0.35 | 0.01-0.02 | 0.01-0.02 | 0.02-0.06 | 1.50-1.90 | 0.01-0.10 | 0.30-0.45 | 0.01-0.02 | 0.003-0.004 | 2.5-4 |
| Typical Result | 90% Ar, 10% CO2 | 0.04-0.08 | 1.10-1.65 | 0.20-0.35 | 0.01-0.02 | 0.01-0.02 | 0.03-0.07 | 1.60-1.90 | 0.01-0.10 | 0.30-0.45 | 0.01-0.02 | 0.003-0.004 | 2.5-4 |
TYPICAL OPERATING PROCEDURES
| Diameter in (mm) | Polarity | Shielding Gas | CTWD⁽¹⁾ mm (in) | Wire Feed Speed m/min (in/min) | Voltage (volts) | Current (amps) | Melt-Off Rate kg/hr (lb/hr) | Deposition Rate kg/hr (lb/hr) | Efficiency (%) |
|---|---|---|---|---|---|---|---|---|---|
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 5.1 (200) | 21-23 | 170 | 2.4 (5.3) | 2.2 (4.7) | 89 |
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 6.4 (250) | 23-25 | 195 | 3.0 (6.7) | 2.7 (6.0) | 90 |
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 8.9 (350) | 25-27 | 250 | 4.3 (9.4) | 3.8 (8.4) | 89 |
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 11.4 (450) | 27-29 | 285 | 5.4 (11.9) | 5.2 (11.4) | 96 |
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 14.0 (550) | 29-31 | 330 | 6.6 (14.5) | 6.4 (14.1) | 97 |
| 0.045 (1.1) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 16.6 (650) | 31-33 | 360 | 7.8 (17.3) | 7.7 (16.9) | 98 |
| 0.052 (1.3) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 5.1 (200) | 22-24 | 225 | 3.2 (7.1) | 2.9 (6.5) | 91 |
| 0.052 (1.3) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1)) | 6.4 (250) | 24-26 | 260 | 4.0 (8.8) | 3.6 (7.9) | 90 |
| 0.052 (1.3) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 8.9 (350) | 26-28 | 295 | 5.6 (12.4) | 5.3 (11.8) | 95 |
| 0.052 (1.3) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 11.4 (450) | 28-30 | 345 | 7.2 (15.9) | 7.1 (15.6) | 98 |
| 0.052 (1.3) | DC+ | 90% Ar, 10% CO2 | 19-25 (3/4-1) | 14.0 (550) | 30-32 | 400 | 8.7 (19.2) | 8.6 (18.9) | 98 |
| 1/16 (1.6) | DC+ | 90% Ar, 10% CO2 | 25-32 (1-1 1/4) | 5.1 (200) | 23-25 | 260 | 4.4 (9.7) | 4.0 (8.9) | 91 |
| 1/16 (1.6) | DC+ | 90% Ar, 10% CO2 | 25-32 (1-1 1/4) | 6.4 (250) | 26-28 | 300 | 5.5 (12.1) | 5.2 (11.4) | 94 |
| 1/16 (1.6) | DC+ | 90% Ar, 10% CO2 | 25-32 (1-1 1/4) | 8.9 (350) | 28-30 | 360 | 7.7 (16.9) | 7.5 (16.5) | 98 |
| 1/16 (1.6) | DC+ | 90% Ar, 10% CO2 | 25-32 (1-1 1/4) | 11.4 (450) | 30-32 | 420 | 9.9 (21.8) | 9.7 (21.3) | 98 |
NOTES
| Name |
|---|
| ⁽¹⁾ To estimate ESO, subtract 3/16 in (4.8 mm) from CTWD. |
| NOTE: Consult steel manufacturer’s recommendations regarding minimum and maximum pre-heat temperature, interpass temperature, and heat input. |