25lb plastic spool Innershield NR-305
The image shown is for representation purposes only and may not reflect the actual product.

Diameters / Packaging

Diameters
33 lb Spool
500 lb Accu-Trak® Drum
0.045 in (1.1 mm) ED033904
0.052 in (1.3 mm) ED033905 ED033908

Metalshield® MC®-90

Metal-Cored Gas-Shielded (GMAW-C)

CLASSIFICATIONS:
E90C-K3 H4
E90T15-M20A6-K3-H4

Metalshield® MC®-90 from Lincoln Electric is a low alloy metal-cored wire designed for high strength welding where tensile requirements of 620 MPa (90ksi) are required.

DETAILS

Metalshield® MC®-90 from Lincoln Electric is a low alloy metal-cored wire designed for high strength welding where tensile requirements of 620 MPa (90ksi) are required.

Features

  • H4 diffusible hydrogen levels
  • Low spatter and excellent arc stability
  • Deoxidizing agents minimize pre- and post-weld clean up
  • Enhanced silicon island management
  • Low temperature impact properties - charpy V-notch test results capable of exceeding 40 J (30 ft·lbf) at -51°C (-60°F)
  • Excellent bead shape and profile

Typical Applications

  • Robotics/hard automation
  • HSLA steels (i.e., ASTM A678 and A710)
  • Crane fabrication
  • Structural

Welding Positions

  • All

Shielding Gas

  • Mixed Shielding Gas

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.28 E90C-K3-H4
AWS AWS A5.36 E90T15-M20A6-K3-H4, E90T15-M21A6-K3-H4
CWB CWB/CSA E90C-K3 H4
ISO ISO T62 6 T15-0 M A-N3M2 H5

MECHANICAL PROPERTIES

Classification Shielding Gas Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -40°C (-40°F)
Charpy V-Notch
J (ft-lbs) @ -51°C (-60°F)
E90C-K3-H4 Requirement 540 (78) min. 620 (90) min. 18 min. Not Specified 27 (20) min.
E90T15-M20A6-K3-H4 Requirement 540 (78) min. 620-760 (90-110) 17 min. Not Specified 27 (20) min.
Typical Result, As-welded 75% Ar, 25% CO2 585-685 (85-100) 655-755 (95-105) 19-27 60-93 (44-68) 36-87 (27-64)
Typical Result, As-welded 90% Ar, 10% CO2 585-725 (85-105) 655-825 (95-120) 18-25 41-100 (30-74) 27-91 (20-67)

DEPOSIT COMPOSITION

Classification Shielding Gas %C %Mn %Si %S %P %Cu %Ni %Cr %Mo %V %B Diffusible Hydrogen
mL/100g Weld Metal
E90C-K3-H4 Requirement 0.15 max. 0.75-2.25 0.80 max. 0.025 max. 0.025 max. 0.35 max. 0.50-2.50 0.15 max. 0.25-0.65 0.03 max. Not Specified 4.0 max.
E90T15-M20A6-K3-H4 Requirement 0.15 max. 0.75-2.25 0.80 max. 0.030 max. 0.030 max. Not Specified 1.25-2.60 0.15 max. 0.25-0.65 0.05 max. Not Specified 4 max.
Typical Result 75% Ar, 25% CO2 0.04-0.08 1.00-1.51 0.20-0.35 0.01-0.02 0.01-0.02 0.02-0.06 1.50-1.90 0.01-0.10 0.30-0.45 0.01-0.02 0.003-0.004 2.5-4
Typical Result 90% Ar, 10% CO2 0.04-0.08 1.10-1.65 0.20-0.35 0.01-0.02 0.01-0.02 0.03-0.07 1.60-1.90 0.01-0.10 0.30-0.45 0.01-0.02 0.003-0.004 2.5-4

TYPICAL OPERATING PROCEDURES

Diameter in (mm) Polarity Shielding Gas CTWD⁽¹⁾ mm (in) Wire Feed Speed m/min (in/min) Voltage (volts) Current (amps) Melt-Off Rate kg/hr (lb/hr) Deposition Rate kg/hr (lb/hr) Efficiency (%)
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 5.1 (200) 21-23 170 2.4 (5.3) 2.2 (4.7) 89
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 6.4 (250) 23-25 195 3.0 (6.7) 2.7 (6.0) 90
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 8.9 (350) 25-27 250 4.3 (9.4) 3.8 (8.4) 89
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 11.4 (450) 27-29 285 5.4 (11.9) 5.2 (11.4) 96
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 14.0 (550) 29-31 330 6.6 (14.5) 6.4 (14.1) 97
0.045 (1.1) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 16.6 (650) 31-33 360 7.8 (17.3) 7.7 (16.9) 98
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 5.1 (200) 22-24 225 3.2 (7.1) 2.9 (6.5) 91
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1)) 6.4 (250) 24-26 260 4.0 (8.8) 3.6 (7.9) 90
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 8.9 (350) 26-28 295 5.6 (12.4) 5.3 (11.8) 95
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 11.4 (450) 28-30 345 7.2 (15.9) 7.1 (15.6) 98
0.052 (1.3) DC+ 90% Ar, 10% CO2 19-25 (3/4-1) 14.0 (550) 30-32 400 8.7 (19.2) 8.6 (18.9) 98
1/16 (1.6) DC+ 90% Ar, 10% CO2 25-32 (1-1 1/4) 5.1 (200) 23-25 260 4.4 (9.7) 4.0 (8.9) 91
1/16 (1.6) DC+ 90% Ar, 10% CO2 25-32 (1-1 1/4) 6.4 (250) 26-28 300 5.5 (12.1) 5.2 (11.4) 94
1/16 (1.6) DC+ 90% Ar, 10% CO2 25-32 (1-1 1/4) 8.9 (350) 28-30 360 7.7 (16.9) 7.5 (16.5) 98
1/16 (1.6) DC+ 90% Ar, 10% CO2 25-32 (1-1 1/4) 11.4 (450) 30-32 420 9.9 (21.8) 9.7 (21.3) 98

NOTES

Name
⁽¹⁾ To estimate ESO, subtract 3/16 in (4.8 mm) from CTWD.
NOTE: Consult steel manufacturer’s recommendations regarding minimum and maximum pre-heat temperature, interpass temperature, and heat input.