Outershield Wire, 25 LB Plastic Spool
The image shown is for representation purposes only and may not reflect the actual product.

Diameters / Packaging

Diameters
50 lb Coil
500 lb Speed Feed® Drum
3/32 in (2.4 mm) ED030236 ED030360

Outershield® XLH70

Flux-Cored Gas-Shielded (FCAW-G)

CLASSIFICATIONS:
E70T-9C-H8
E70T1-C1A2-CS1-H8

Outershield® XLH-70 has low diffusible hydrogen levels and the best temperature impact properties of any Lincoln Electric E70T-1 electrodes.

DETAILS

Provides best in class wire feeding performance with controlled H8 diffusible hydrogen levels. It is an excellent choice for structural fabrication and heavy equipment applications in the flat and horizontal positions.

Features

  • Meets AWS D1.8 seismic lot waiver requirements for critical welds
  • H8 diffusible hydrogen levels - controlled for high resistance to hydrogen induced

Typical Applications

  • Structural fabrication
  • Seismic applications
  • Heavy equipment
  • Machinery fabrication
  • General fabrication

Welding Positions

  • Flat/Horizontal

Shielding Gas

  • 100% CO2

Disclaimers

Warning -

Cancer and Reproductive Harm -

www.P65Warnings.ca.gov

BEFORE USE, READ AND UNDERSTAND THE SAFETY DATA SHEET (SDS) FOR THIS PRODUCT AND SPECIFIC INFORMATION PRINTED ON THE PRODUCT CONTAINER. SDS Search page

See test result disclaimer

CONFORMANCE

CONFORMANCES SPECIFICATION CLASSIFICATION
AWS AWS A5.20 E70T-1C-H8, E70T-9C-H8
AWS AWS A5.36 E70T1-C1A2-CS1-H8
ABS ABS - Part 2 3YSA H5

MECHANICAL PROPERTIES

Classification Shielding Gas Polarity Yield Strength @ 0.2% Offset
MPa (ksi)
Tensile Strength
MPa (ksi)
Elongation
%
Charpy V-Notch
J (ft-lbs) @ -20°C (0°F)
Charpy V-Notch
J (ft-lbs) @ -30°C (-20°F)
E70T-1C-H8 Requirement 100% CO2 DC+ 400 (58) min. 480-660 (70-95) 22 min. 27 (20) min.
E70T-9C-H8 Requirement 100% CO2 DC+ 400 (58) min. 480-660 (70-95) 22 min. 27 (20) min.
E70T1-C1A2-CS1-H8 Requirement 100% CO2 DC+ 400 (58) min. 480-660 (70-95) 22 min. 27 (20) min.
Typical Result, As-welded 100% CO2 DC+ 500 (72) 580-630 (84-91) 24 65-126 (48-93) 49-156 (36-115)

DEPOSIT COMPOSITION

Classification Shielding Gas Polarity %C %Mn %P %S %Si Diffusible Hydrogen
mL/100g Weld Metal
E70T-1C-H8 Requirement 100% CO2 DC+ 0.12 max. 1.75 max. 0.03 max. 0.03 max. 0.90 max. 8.0 max.
E70T-9C-H8 Requirement 100% CO2 DC+ 0.12 max. 1.75 max. 0.03 max. 0.03 max. 0.90 max. 8.0 max.
E70T1-C1A2-CS1-H8 Requirement 100% CO2 DC+ 0.12 max. 1.75 max. 0.030 max. 0.030 max. 0.90 max. 8 max.
Typical Result 100% CO2 DC+ 0.06-0.08 1.43-1.69 0.014 max. 0.014 max. 0.53-0.64 3.8-7.5

TYPICAL OPERATING PROCEDURES

Diameter Shielding Gas Polarity CTWD
mm (in.)⁽¹⁾
Wire Feed Speed
m/min (in/min)
Voltage
volts
Approx. Current
amps
Melt-off Rate
kg/hr (lb/hr)
Deposition Rate
kg/hr (lb/hr)
Efficiency
%
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-1/4) 3.8 (150) 23-26 345 6.5 (14.4) 5.6 (12.4) 86
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-1/4) 5.1 (200) 27-30 445 8.7 (19.2) 7.6 (16.8) 87
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-1/4) 6.4 (250) 28-31 510 10.9 (24.0) 9.5 (21.0) 87
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-1/4) 7.6 (300) 30-32 570 13.1 (28.8) 11.4 (25.2) 87
3/32 in (2.4 mm) 100% CO2 DC+ 32 (1-1/4) 8.3 (325) 31-33 600 14.2 (31.2) 12.4 (27.3) 87

NOTES

Note
⁽¹⁾ To estimate ESO, subtract 1/4 in. (6.0 mm) from CTWD.